NEW 1995-APPROX. 5 YEARS USE
Specifications:
COMPONENTS....POWER CHAIN TYPE CONVEYOR
....BINKS PAINT BOOTH
....INFRA RED DRY OFF OVEN
....GAS FIRED FINISHING OVEN
....FORCED AIR COOLING TUNNEL
....ENVIRONMENTAL ROOM
....ALLEN BRADLEY 540 PLC CONTROL
....NORDSON GUN CONTROLS
BOOTH SPECS:
LINE SPEED.........16 FPM
WORK OPENING.......18.25" X 48" HIGH
AUTOMATIC GUNS.....8(4 EACH SIDE)
GUN CONTROL........NORDSON VERSA SPRAY II SURE COAT
POWDER RECOVERY....(2) UNITS
RECIPROCATORS......2 BINKS 2000P PROGRAMMABLE
BINKS SOFT TOUCH RECOVERY UNIT
POWDER HOPPER 175 LB.
UV/IR FLAME DETECTION SYSTEM
FINISHING OVEN: TYPE...GAS FIRED
FUEL..................NATURAL GAS @ 1-5 PSIG
2,000 CFH @ 1,000 BTU/SCF
2,000,000 BTUH
RECIRCULATION.........(2) 19,000 CFM @ 20 HP
EXHAUST...............1500 CFM @ 1/2 HP
TEMPERATURE...........500 DEGREE MAX. 385 DEGREE NORMAL
ELECTRICAL............480V/3PH/60HZ APPROX. 50 AMPS
ENVIRONMENTAL ROOM: INSULATED
AIR CONDITIONED
HUMIDITY CONTROL
30 TON TRANE AIR UNIT
SITE INSPECITON:
PENDING
|
No photo available
|
|
|
 |